Deliverables list

For detailed information see the deliverables description or choose the report on the deliverables in below table. 

 

Del.
no.

Deliverable name

Documents

WP
no.

Lead
partici-
pant

Estimat.
person
months

Nature

 

Dissemi
nation
level

Delivery
date
(project
month)

D1

Creation of NEMIS website

Abstract, Report

6

1

2

O

PU

m3

D2

Report on specifications of VCSEL performance parameters

Abstract

1

4

3

R

RE

m6

D3

Definition, verification, unification of diagnostics and characterisation methods for VCSEL structures and devices (incl. ageing conditions)

Abstract

4

3

8

R

PU

m6

D4

VCSEL structure for emission at ~2.3 µm (+/- 100 nm) epitactically grown

Abstract, report

2

2

20

R

RE

m9

D5

Report on first electrically pumped VCSEL (2.3 µm +/- 100nm)

Abstract

3

1

20

R

PU

m12

D6

First annual activity report

Abstract

6

1

5

R

RE

m13

D7

Delivery of 10 electrically pumped room-temperature operating 2.3 µm VCSELs to WP 5

Abstract 

3

1

7

P

RE

m15

D8

VCSEL structure for emission at ~ 2.7 µm (+/- 100nm) epitactically grown

Abstract 

2

2

23

R

RE

m18

D9

Early demonstrator platform gas monitor based on WMS with absorbance sensitivity <10-4

Abstract 

5

6

24

D

RE

m18

D10

Report on optimum VCSEL designs (electrical, thermal, optical) and their predicted performance (threshold gain, power, efficiency, modal and beam parameters)

Abstract 

1

4

15

R

RE

m24

D11

VCSEL structure for emission at ~ 3.3 µm (+/- 100nm) epitactically grown

Abstract 

2

2

14

R

RE

m24

D12

Report on comparison of device concepts for oxide-confined and BTJ GaSb-VCSELs

Abstract 

3

1

22

R

RE

m24

D13

Second annual activity report

Abstract

6

1

5

R

RE

m25

D14

Demonstrator of compact-size ammonia sensor based on PAS with

detection limit < 100ppb

  Abstract

5

6

23,5

D

RE

m27

D15

Measurement and characterisation of laser structures

  Abstract

4

3

57

R

CO

m30

D16

Improved demonstrator platform gas monitor based on WMS with absorbance sensitivity <10-4, long-term-stable: baseline drift 
< 10-4/month

 Abstract

5

6

12

D

RE

m33

D17

Report on analysis of VCSEL performance

 Abstract

1

4

13

R

RE

m36

D18

Final report on device technology and fabrication techniques for the VCSEL devices

 Abstract

3

1

25

R

PU

m36

D19

Characterisation and tests of laser devices for gas sensing

 Abstract

4

3

12

R

CO

m36

D20

Demonstrator of 13CO2/12CO2  sensing system based on PAS with

0.1% resolution

 Abstract

5

6

4

D

RE

m36

D21

Report on analysis of VCSEL performance and on their use in gas analysis systems

 Abstract

5

6

4

R

PU

m36

D22

Third annual activity report

 

6

1

6

R

RE

m37